Hydraulic valves

Explore hydraulic valves by circuit function: preventing reverse flow, regulating flow, limiting pressure, controlling loads and dividing flow. This catalogue focuses on model data and primary technical references.

Choose a valve function

How to select

First identify the required hydraulic function and inspect the circuit symbol. Compare flow capacity, maximum pressure, port connections and adjustment range as separate specifications. A valve setting or adjustment limit is a different parameter from its maximum pressure rating.

For piloted valves, read the pilot ratio in the convention used by the source catalogue. Match the exact model and product revision when checking installation dimensions or replacement compatibility.

Related catalogue: Directional valves for modular flow-routing controls.

Technical references

Technical documentation: verification pending

Technical documentation examples

Double acting overcenter valve FPOE40D3/8LA20 (3/8'' BSP, 40l/min)

Double acting overcenter valve FPOE40D3/8LA20 (3/8'' BSP, 40l/min)

Maximum flow (L/min):40
Maximum pressure (bar):350
Port connection:3/8" BSP
Valve setting (bar):200
View
Double acting overcenter valve FPOE40D3/8LA35 (3/8'' BSP, 40l/min)

Double acting overcenter valve FPOE40D3/8LA35 (3/8'' BSP, 40l/min)

Maximum flow (L/min):40
Maximum pressure (bar):350
Port connection:3/8" BSP
Valve setting (bar):250
View
Double acting overcenter valve FPOEB120D3/4LA20 (3/4'' BSP, 120l/min)

Double acting overcenter valve FPOEB120D3/4LA20 (3/4'' BSP, 120l/min)

Maximum flow (L/min):120
Maximum pressure (bar):250
Port connection:3/4" BSP
Valve setting (bar):200
View
Double acting overcenter valve FPOEB120D3/4LA35 (3/4'' BSP, 120l/min)

Double acting overcenter valve FPOEB120D3/4LA35 (3/4'' BSP, 120l/min)

Maximum flow (L/min):120
Maximum pressure (bar):250
Port connection:3/4" BSP
Valve setting (bar):250
View
Double acting overcenter valve FPOEB70D1/2LA20 (1/2'' BSP, 70l/min)

Double acting overcenter valve FPOEB70D1/2LA20 (1/2'' BSP, 70l/min)

Maximum flow (L/min):70
Maximum pressure (bar):250
Port connection:1/2" BSP
Valve setting (bar):200
View
Double acting overcenter valve FPOEB70D1/2LA35 (1/2'' BSP, 70l/min)

Double acting overcenter valve FPOEB70D1/2LA35 (1/2'' BSP, 70l/min)

Maximum flow (L/min):70
Maximum pressure (bar):250
Port connection:1/2" BSP
Valve setting (bar):250
View
Double acting overcenter valve OBDL3/820 (3/8'' BSP, 50l/min)

Double acting overcenter valve OBDL3/820 (3/8'' BSP, 50l/min)

Maximum flow (L/min):50
Maximum pressure (bar):315
Port connection:3/8" BSP
View
Double acting overcenter valve OBDL3/835 (3/8'' BSP, 50l/min)

Double acting overcenter valve OBDL3/835 (3/8'' BSP, 50l/min)

Maximum flow (L/min):50
Maximum pressure (bar):315
Port connection:3/8" BSP
View
Double acting overcenter valve ODNG6/60-350 (Cetop-3, 60l/min)

Double acting overcenter valve ODNG6/60-350 (Cetop-3, 60l/min)

Maximum pressure (bar):350
Catalog pilot ratio:4.25:1
View
Double acting overcenter valve VT0120063535 (3/8'' BSP, 50l/min)

Double acting overcenter valve VT0120063535 (3/8'' BSP, 50l/min)

Maximum flow (L/min):50
Maximum pressure (bar):350
Port connection:3/8" BSP
Valve setting (bar):280
View
Double acting overcenter valve VT0120085035 (1/2'' BSP, 50l/min)

Double acting overcenter valve VT0120085035 (1/2'' BSP, 50l/min)

Maximum flow (L/min):50
Maximum pressure (bar):350
Port connection:1/2" BSP
Valve setting (bar):280
View
Double acting overcenter valve VT0160063520 (3/8'' BSP, 50l/min)

Double acting overcenter valve VT0160063520 (3/8'' BSP, 50l/min)

Maximum flow (L/min):50
Maximum pressure (bar):350
Port connection:3/8" BSP
Catalog pilot ratio:1:4,25
Valve setting (bar):170
View
Showing 649 to 660 of 2245 (188 Pages)