Hydraulic valves

Explore hydraulic valves by circuit function: preventing reverse flow, regulating flow, limiting pressure, controlling loads and dividing flow. This catalogue focuses on model data and primary technical references.

Choose a valve function

How to select

First identify the required hydraulic function and inspect the circuit symbol. Compare flow capacity, maximum pressure, port connections and adjustment range as separate specifications. A valve setting or adjustment limit is a different parameter from its maximum pressure rating.

For piloted valves, read the pilot ratio in the convention used by the source catalogue. Match the exact model and product revision when checking installation dimensions or replacement compatibility.

Related catalogue: Directional valves for modular flow-routing controls.

Technical references

Technical documentation: verification pending

Technical documentation examples

Normally open 2 ways valve VCF12NA220CC

Normally open 2 ways valve VCF12NA220CC

Maximum flow (L/min):60
Coil voltage (V):220
Electrical supply:Rectified AC
Port thread:1/2" BSP
View
Normally open 2 ways valve VCF12NA24CC

Normally open 2 ways valve VCF12NA24CC

Maximum flow (L/min):60
Coil voltage (V):24
Electrical supply:DC
Port thread:1/2" BSP
View
Normally open 2 ways valve VCF34NA12CC

Normally open 2 ways valve VCF34NA12CC

Maximum flow (L/min):120
Coil voltage (V):12
Electrical supply:DC
Port thread:3/4" BSP
View
Normally open 2 ways valve VCF34NA220CC

Normally open 2 ways valve VCF34NA220CC

Maximum flow (L/min):120
Coil voltage (V):220
Electrical supply:Rectified AC
Port thread:3/4" BSP
View
Normally open 2 ways valve VCF34NA24CC

Normally open 2 ways valve VCF34NA24CC

Maximum flow (L/min):120
Coil voltage (V):24
Electrical supply:DC
Port thread:3/4" BSP
View
Normally open 2 ways valve VCF38NA12CC

Normally open 2 ways valve VCF38NA12CC

Maximum flow (L/min):40
Coil voltage (V):12
Electrical supply:DC
Port thread:3/8" BSP
View
Normally open 2 ways valve VCF38NA220CC

Normally open 2 ways valve VCF38NA220CC

Maximum flow (L/min):40
Coil voltage (V):220
Electrical supply:Rectified AC
Port thread:3/8" BSP
View
Normally open 2 ways valve VCF38NA24CC

Normally open 2 ways valve VCF38NA24CC

Maximum flow (L/min):40
Coil voltage (V):24
Electrical supply:DC
Port thread:3/8" BSP
View
NPT Check-valve line mounting VT001004NPT

NPT Check-valve line mounting VT001004NPT

Maximum flow (L/min):12
Maximum pressure (bar):350
Port connection:1/4" NPT
Valve setting (bar):0.5
View
NPT Check-valve line mounting VT001006NPT

NPT Check-valve line mounting VT001006NPT

Maximum flow (L/min):30
Maximum pressure (bar):350
Port connection:3/8" NPT
Valve setting (bar):0.5
View
NPT Check-valve line mounting VT001008NPT

NPT Check-valve line mounting VT001008NPT

Maximum flow (L/min):45
Maximum pressure (bar):320
Port connection:1/2" NPT
Valve setting (bar):0.5
View
NPT Check-valve line mounting VT001012NPT

NPT Check-valve line mounting VT001012NPT

Maximum flow (L/min):85
Maximum pressure (bar):300
Port connection:3/4" NPT
Valve setting (bar):0.5
View
Showing 1045 to 1056 of 2245 (188 Pages)